Skip to main content
separable helix (induction) coil
separable helix (induction) coil

separable helix (induction) coil

Date1842-1855
Inventory Number0444
ClassificationInduction Coil
Subject
    Attributed to Daniel Davis, Jr. 1813 - 1887
    Cultural Region
      Place of Origin
        Dimensions23.6 × 9.9 × 9.5 cm (9 5/16 × 3 7/8 × 3 3/4 in.)
        Material
          Bibliography
          DescriptionThis coil is made of a simple winding of thin insulated wire. Its two ends connect to a brass screw connector at top and bottom of the coil. The insulated is green. The coil was used in vertical orientation with other parts which are missing.

          This design is unusual in that the secondary (outer) and primary (inner) coils were separable from each other, instead of being wound directly over each other, as was done for most subsequent induction coils. Unfortunately, only the outer coil survives in this collection. The inner coil was most likely mounted and fixed on a base, according to Davis's original design.

          Davis sold the whole apparatus, with handles for shock, between $12.00 and $18.00 in 1842.
          Signedunsigned
          Curatorial RemarksThis electromagnet served several purposes, as described by Davis in his books of magnetism. It was used in medicine, for example, with shock handles, with or without a clockwork electrotome. This type of upright coil is also illustrated in Farrar's and Loverings' book (1842), pp. 298-299. The instrument is described as Page's design and illustrated in Joseph Abbot, "Description of Several new Electro-Magnetic and Magnetic-Electric Instruments,'' <i>American Journal of Science</i> 40 (1841): 109.
          FunctionFor lecture demonstration in physics as well as medical use. The battery was connected across the missing inner (primary) coil. When the battery connection was interrupted, either by rubbing across a steel rasp (see 0118) or by an electrotome (see 0120), high voltage pulses were induced in the outer (secondary) coil, which the patient received by holding shock handles connected to the outer coil's ends.
          ProvenanceFrom the Department of Physics, Jefferson Laboratory, Harvard University.
          inductance coil for medical use
          Daniel Davis, Jr.
          Date: circa 1842
          Object number: 0118
          inductance coil for medical use
          Daniel Davis, Jr.
          Date: circa 1848
          Accessories: battery (0566b); pair of shock handles (0566c,d)
          Object number: 0566a
          vibrating electrotome with induction coil (missing)
          Daniel Davis, Jr.
          Date: 1848-1855
          Object number: 0120
          apparatus for showing induction of the earth
          Daniel Davis, Jr.
          Date: 1848-1855
          Object number: 0105
          flat spiral (or ribbon) coil
          Daniel Davis, Jr.
          Date: 1842-1855
          Object number: 0103
          flat spiral (or ribbon) coil
          Daniel Davis, Jr.
          Date: 1842-1855
          Object number: 0101
          flat spiral (or ribbon) coil
          Daniel Davis, Jr.
          Date: 1842-1855
          Object number: 0102
          Zn-Cu battery
          Daniel Davis, Jr.
          Date: circa 1848
          Object number: 0566b
          induction coil
          Daniel Davis, Jr.
          Date: 1842-1855
          Object number: 0110c
          Page's revolving electromagnet
          Daniel Davis, Jr.
          Date: 1842-1855
          Object number: 0122
          rectangle electromagnet revolving on its axis
          Daniel Davis, Jr.
          Date: 1848-1855
          Object number: 0112
          pair of handles for giving electric shocks
          Daniel Davis, Jr.
          Date: circa 1848
          Object number: 0566c,d